Glass performance data. To get started, input your required performance data below.

Glass performance data When coupled with conventional clear glass in a one-inch insulating glass unit (IGU), Solarban ® 70 glass outshines the performance of any other solar control low‑e glass on the market today. GlassNET Login. Heat-strengthened glass is approximately 2 x stronger than annealed glass. SGG Sapphire Blue. Launch another simulation. 6. Supporting Sustainable Design All data are calculated using spectral measurements that conform to standards ISO 9050 (2003) (light & energy performances), EN 673 and NFRC 100-2010/200-2010 (U-values) and are subjected to change without prior notice. Glass Analytics online tools offer a comprehensive suite of engineering and analytical reports A leader in tools for the glass industry. itiglass. 81 5. Performance Safety All performance data calculated using LBNL Window 7. Table 2 lists data for low iron glass. Solar energy glass Anti-reflective Solar Control Low-E Glass Energy E˜ciency High Performance Low-E Glass Our Low-E coatings o˚er e˜cient energy saving bene˛ts to any architectural project, minimizing the amount of ultraviolet and infrared light that passes through the glass without compromising the amount of visible light transmittance. NFRC 100 – 2010 conditions have been used. Find the perfect glass solutions for your projects today. Fill out the form to access the glass performance data of GlassecViracon’s reference products. Kien Safety Glass was incorporated in 2002, over the years the company has seen doses of healthy growth, Refshine Performance Data. Tdw ISO/CIE Indoor Glass Temperature (°F) Trans Reflectance Out In Air Argon Winter Summer Clear Clear 80% 15% 15% 0. This could be monolithic glass, plastic, laminates, applied films on glass, or thin-film coated glass. Due to its clarity, consistency and solar control performance, Solarban ® 70 glass has become the most commonly specified triple-silver-coated glass in the industry. Not only does this allow abundant light through, it gently diffuses it to create environments that seem to glow. Title Image/pdf; Performance parameters AIS Clear: Performance parameters AIS Tinted: Performance parameters AIS Opal: Performance parameters AIS Sunshield: Performance parameters AIS Ecosense: 531k. Actual performance and results can vary depending on the circumstances. 0 All figures quoted in this datasheet are indicative of typical product properties. LoĒ³-366 is the ultimate performance glass, with energy savings throughout the year, in every part of the country. Data is based on testing ~36" x 84" glass to ASTM E413-87 in an acoustical Note: Data is based on laboratory spectrophotometric measurements and produced using Windows software for AFRC 100-2010 conditions, which is the internationally recognised method for describing glass performance. AGC cannot be held responsible for any deviation between the data introduced and the conditions on site. Analysis data supplied by PPG Industries and Cardinal Glass for glass as used in Metropolitan High Performance Windows’ vinyl windows and doors and may not apply to products as produced by other manufacturers. Bonus: you can get the glazing ACOUSTICS reference data and Glass color. The laminated glass units are constructed with two lites of glass and an interlayer. Published on Apr 4, 2017. Submission failed due to a error, please try again Special acoustic PVB interlayers are also available for further improving the sound control performance of glass. With Air/Argon/Krypton/Xenon different Performance Data is not currently available for this glass make-up, please launch a new simulation or go to Glass Analytics to configure performance data for your required glass make-up. For even better performance, combine Solarbronze ® glass with Sungate ® 400 glass in a one-inch IGU to improve solar control performance and lower U‑values. 00 Outside Glass: Inside Glass: Nominal Thickness: VLT (%) U Value: SHGC: Selectivity: PerformaTech™ PH08 Clear: PerformaTech™ PH08: VFloat™ Clear: 6+12+6: 68: 1. Call today to speak to an expert today (800) 995-8878. mm. 25-inch (6mm) Lites Glass Type Outdoor Lite: Coating (Surface) Glass The results represent Center-of-Glass performance data based on ANSI/NFRC 100 and ANSI/NFRC 200 Environmental Design Conditions utilizing the LBNL Overview. 75 5. SunGuard SNX 51/23 low-E coated glass is an excellent choice whether aesthetics or performance is your goal. 0 7 21 34 27 36 30 [1] Figures may vary due to manufacturing tolerances. *OITC is estimated based on this test. 34 to 0. Sun Ban from Saint-Gobain is a best-in-class range of Solar Control Glass for residences. Asymmetrical lay-ups, having two different thicknesses of glass, are also available on request. These comprehensive charts present an in-depth breakdown of performance characteristics across vital categories for our diverse glass products. All laminated safety glass also meets ANSI Z97. 4, 7. To achieve spectrally selective glass, as recommended by the U. 52mm Clear PVB + 6mm Sunergy #4 All data are calculated using spectral measurements that conform to standards ISO 9050 (2003) (light & energy performances), EN 673 and NFRC 100-2010/ Glass can provide buildings with an abundance of natural light and protection from the elements. • As a guide when frames are included, the Rw values shown will decline. Solarban ® 60 Starphire ® glass can help you achieve your design vision of a glass building with the ultimate in transparency and Glass Performance Data. 3 software. Understanding glass performance begins by understanding some key glass performance terms. Thermal Cracks of Glass. Use the calculator to model the thermal and optical properties for your glass Argon data based on 10% air and 90% argon. The monolit hic glass is one lite of glass. com or The glass has improved performance and higher exterior visible-reflectivity with a metallic sheen when installed with the coating on the first surface. Contact AGC Technical Services to ensure The performance data below applies to laminated glass units constructed with two plies of glass and an interlayer. However, when used as clear single window glazing, it is less effective in controlling the indoor climate and promoting energy efficiency. No uncontrolled water when tested at 10 psf. The performance data below applies to triple insulating glass units single glass performance values vlt visible light transmission vlr visible light reflectance vlri visible light reflectance shgc u-value colour and type % external % internal % w/m2k clear float 3mm 90 8 8 0. A potential 6 dB performance loss between a based center-of-glass performance for many prospective glazing compositions. Performance data. Floor to ceiling windows provide light, transparency and sweeping views of Central Park Centre of Glass (COG) performance data as contained in this document can be calculated for single glazed, IGUs or laminated glass which is constructed using LBNL’s Optics program then imported into the Window program. Guardian SatinDeco® is a translucent, satin-feel glass that also has a high level of natural light transmittance. , U-factor and g-factor) of a window comes from the IGDB. 84 5. Glass selectivity is an index that reports the relationship between visible light transmission and solar heat gain, it is measured as an index (S = Vt/g) with a high selectivity more Refers to the total amount of solar energy transmittance entering a building through the glazing as heat gain. Wind Pressure Resistance of Glass. 75-inch (44mm) units with 0. From technical data sheets to complex technical considerations, Vitro is here to help you make an informed decision on the product you Laminated Glass Construction STC OITC 100 125 160 00 2 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 Frequency (Hz) Sound Transmission Loss (dB) LAMINATED ACOUSTICAL DATA The performance data below applies to laminated glass units. Combined in a one-inch insulating glass unit (IGU) with clear glass, Solarcool ® glasses offer an expansive palette of appearance and performance options with solar heat gain coefficients (SHGCs) ranging from 0. Outside Inside Air Argon Air Glass Acoustic Data Rw values Float mm Rw 3 , 4 30 5 , 6 31 8 34 10 35 12 37 19 39 Duo Plus™ IGU with Float mm Rw 4/12/4 32 5/12/5 33 6/12/6 34 Single Laminated PVB mm Rw 6. Except for the acoustic properties, light properties, energy properties, thermal properties, safety properties, and even thickness & weight included in the file. Overall Guardian glass series are included in the system. 0 Pilkington Sunplus™ MM 3. 7mm Remarkably Neutral. IN. 91 1. For windows, skylights, and glass doors, a U-factor may refer to just the glass or glazing alone. ASTM E‐331. SOLAR PERFORMANCE VALUES [1] Glass Thickness Transmittance Reflactance All tabulated solar performance data are based on the methodology prescribed in ISO 9050, 2003 except Infrared, which is based on the solar irradiance data prescribed by ISO 9050, 2003 from 780 to2500 nm. More from. VLT% - refers to % visible light transmittance. WERS provides members the ability to research the performance values of different glazing options in their framing systems before having them fully simulated. Starphire® Glass Performance Data These tables include metric glass performance for monolithic, laminate and insulating glass units (IGUs). K) (EN 673) U Value (W/m2. Data is based on testing ~36" x 84" glass to ASTM E413-87 in an acoustica l wall. Each category serves as a crucial indicator, offering precise insights into the functional attributes of the glass and facilitating effective comparisons for informed decision-making. Thermal Stress and Thermal Data is based on center of glass performance of representative factory production samples. Performance Safety Insulating Glass Performance Data. 23 solar heat gain coefficient and a high visible light transmission of 51% on a clear-over-clear double-glazed configuration. Glass Analytics online tools offer a comprehensive suite of engineering and analytical reports Emirates Float Glass-Product range offers Architects & Customers a wide choice to meet varying performance criteria distinct aesthetic appeal. If you are looking for a product not listed or have specified performance data for a project and need product suggestions please contact your Mercury SunGuard SN 68 low-E coated glass provides a beautiful, natural look with balanced thermal performance and a 0. PERFORMANCE DATA FOR LOW E AND SOLAR CONTROL GLASS Low E, Solar Control & Reflective Low E, Solar Control & Reflective Clear Glass Double Glazing Glass Make Up 1/4˝ (6 mm) / 1/2˝ (12 mm) Argon 90% / 1/4˝ (6 mm) (*) additional Low E All performance data calculated using LBNL Window 7. 7 10mm 86 7 7 0. Actual values may vary due to the production process and manufacturing tolerances. Follow this publisher. U Value. 77 5. All data are calculated using spectral measurements that conform to standards ISO 9050 (2003) (light & energy performances), EN 673 and NFRC 100-2010/200-2010 (U-values) and are The results represent Center-of-Glass performance data based on ANSI/NFRC 100 and ANSI/NFRC 200 Environmental Design Conditions utilizing the LBNL Performance calculator. PERFORMANCE DATA. Calculate. com or request our Architectural Glass Catalog. Starphire® Glass Performance Data Glass Performance Data. ™ Planibel G™ and Sunergy™ are All performance data calculated using LBNL Window 7. Understand the performance of Vitro Glass products in monolithic configurations or one-inch insulating glass units (IGUs). Data is based on testing ~36" x 84" glass to ASTM E413-87 in an acoustical wall. 37 SHGC. 2 92. Simple Performance Recommendation: This helps you quickly make a recommendation to your client whether their primary need is glare reduction, and Mirage Series Films, a Film To Glass Chart, Tri-Fold Brochures, and a Flat Glass Performance Data Sheet. The monolithic glass is one lite of glass. It is also characterized by high solar heat gain, which means that as well as retaining heating warmth in a room, it allows high level of solar energy to enter, for warmer and brighter interiors, and In addition to functioning with clear glass, Solarban ® 60 glass also can be combined in insulating glass units (IGUs) with an outboard lite of tinted or reflective-tinted glass to increase aesthetic and performance options. Noise source levels dB Threshold of hearing 0 Conversational speech 65 Average traffic (kerbside) 70 Busy Data listed based on NFRC 100-2010 with the following; Single glass data - Low-E coating surface #2 for single glass and surface #4 for laminated glass. 1 file(s) 274 KB. Most of the experimental input data required by the program to calculate the energy performance indices (e. SNX 51/23 offers a low level of outdoor reflectivity of 14%. In the winter, Low-E insulating glass units reflect heat back into the room, blocking as much as 71% of the heat that can escape through conventional double pane glass units. 9 4mm 89 8 8 0. Video Gallery. 3 software representing center of glass performance data. Table 1 provides data for monolithic float glass. K) (Summer The table above shows performance data relating to high performance neutral solar control glasses available on the market with normal lead-in times. The following data sheets include information about the aesthetic and performance of Vitro Architectural Glass products, as well as information about product fabrication and availability. 6mm Grey), then this will dictate any coating to surface #3 as Tinted glass are designed to be as close to the sun as possible to absorb sun heat, stopping it from entering inside, and so tinted glass always go on the external pane. 7 and 7 Resource center AIS Glass Performance Parameters AIS GLASS BLOGS. It is also characterised by high solar heat gain, which means that as well as retaining heating warmth in a room, it allows high level of solar energy to enter, for warmer and brighter interiors in sunny Double Glass Performance Data 1, 10 Single Glass Performance Data 1, 10 Nominal Glass Thickness Visible Light2 Solar Energy2 U-Factor5 Solar Heat Gain 3 Coefficient 7 Shading Coefficient Transmittance 8 Reflectance4 % Transmittance 3 % Reflectance 4 % UV Transmittance 2 % U. • Argon calculations based on 90% gas fill level. 83 0. U-factor is the rate at which a window, door, or skylight transmits non-solar heat flow. Aesthetic Show only: Clear/Neutral Note: Performance data calculations in this table are based on the International Glazing Database (IGDB) Version 28. Customize everything to meet your project’s specifications. For detailed information on the methodologies used to calculate the aesthetic and performance values in this table, please visit vitroglazings. Combining new materials with advanced coating technology and refinements, Solarban ® 90 glass is engineered to outperform even Solarban . Technical Service Bulletins. The low-e coating is on position 3 in double glzed units and on position 2 and 5 in triple glazed units. To obtain samples of any Vitro Glass product, call 1-855-VTRO-GLS (887-6457) or visit samples. Emirates Float Glass-Product range offers Architects & Customers a wide choice to meet varying performance criteria distinct aesthetic appeal. ASTM E‐330. Sun Ban from Saint-Gobain is a best-in-class range of Solar Control Glass for Generate product performance data for custom glass make-ups and create detailed BIM object files for your project. 0. Refer to Viridian Performance Data for more values. 8 Pilkington Optiphon™ 20,8 42 -1 -3 20. • (#) after coating is IGU coating surface number. Transmittance and reflectance values based on spectrophotometric measurements and Performance Data U Value (W/m2. com. SHGC (Solar Heat Gain Coefficient). Cardinal Double-Pane Insulating Glass Performance Data 6 mm / 13. PERFORMANCE DATA for One-Inch Insulating Glass Units. Read more about the tools below Mercury Glass is committed to supplying the Australian and New Zealand glass industries with the most innovative glazing solutions to meet the most challenging contemporary building designs. Pilkington Energy Advantage™ is a pyrolitically on-line coated low-emissivity glass. (2) Calculations based on 13 mm (1/2") airspace, 3 mm (1/8") glass, and 90% Argon gas fill level. First-surface performance data can be modeled in our online eView Construct tool. In this Generate product performance data for custom glass make-ups and create detailed BIM object files for your project. For detailed technical product information, review our Technical Data Sheets below. Additional information. It offers solar control characteristics and high selectivity. 30: 0. Pilkington Thermal Insulation Glass Range – performance data The above performance data has been determined in accordance with EN 410 and EN 673. Scalamirage 26082016. Search. 47 0. K) (Summer- NFRC) VLR ext (%) VLR Int (%) ER (%) Light Performances Energy Performances SF (%) Sunergy SC Laminated, 6mm Clear + 1. 2020-es-gap - 1 - Approximate Sound Levels Onset of To obtain samples of any Vitro Glass product, call 1-855-VTRO-GLS (887-6457) or visit samples. Most window system suppliers have total system (frame and glass) tested values. Actual values All performance data calculated using LBNL Window 7. The glazing make-up suggestions below are pre-defined to provide examples of Please contact Oldcastle BuildingEnvelope ® for product availability and performance data as this information is subject to change without notice. Single & Laminated Glass Data. Less than or equal to. 9 5mm 88 8 8 0. The glazing make-up suggestions below are pre-defined to provide examples of commonly used combinations of products. The results represent Center-of-Glass performance data based on NFRC 100 Environmental Design Conditions utilizing the LBNL Window 7. Product Name For those who demand more from their windows – enhanced style, great versatility and high performance – there’s American vinyl windows with Low-E insulated glass. 14 and The glass delivers a Sound Reduction Factor (Rw) of up to 54 decibels (dB) in triple glazing and 52dB in double glazing. Summer* U. By filtering by Visible Light Transmission, Solar Heat Gain, Reflectance and U-Value you can find a product that meets your requirements Generate product performance data for custom glass make-ups and create detailed BIM object files for your project. Energy Performance Data Energy Technical Information Our Products Energy Glass. Department of Energy, team *Comparisons based on centre of glass performance data in NFRC standards between regular 6mm Clear Float Glass and 24mm Insulglass Select ® Clear, Neutral and Grey Double Glazed Units of 6/12/6 and argon gas. Glass Type. Performance data is calculated using both LBNL Window 7. The results represent Center-of-Glass performance data based on ANSI/NFRC 100 and ANSI/NFRC 200 Environmental Design Conditions utilizing the LBNL Window 7. 3mm Exterior Glass Interior Glass Visible Light SHGC For additional glass configurations use our AGC Glass Calculator. These products consist of a multi-layer construction using standard PVB with a special soft acoustic core: It is calculated based on ASTM E 1332 using sound transmission loss data measured between 80 – 5000 Hz. Read more about the tools below, or register and start using Glass Generate product performance data for custom glass make-ups and create detailed BIM object files for your project. April 4, 2017. * Data based on using Starphire® glass for both interior and exterior lites. 8132 SYSTEM DETAILS PERFORMANCE DATA AIR. 26. 45 45 96 48% 70 Use the following product selection tool to find specific glass products by their performance statistics. 72 0. 5-inch (13mm) airspaces and three 0. AIS MASTERCLASS PERFORMANCE PARAMETERS. com or A leader in tools for the glass industry. The data is glass only and care should be exercised when evaluating manufacturer’s published data that the same environmen-tal conditions have been used. (1) Applies to CPSC 16 CFR 1201 and CAN/CGSB-12. Pilkington EverGreen™ provides high light transmittance when compared to other tinted float glasses while still providing solar control, resulting in a high selective glass. All performance data PDF; Guide to using single glazing performance data PDF; Guide to using IGU performance data PDF; WPEG (Windows Performance Estimation Guide) - Insulated Glazing Units PDF; WPEG (Windows Performance Estimation Guide) - Single Glazing PDF; Thermal Stress and Thermal Fracture. The glazing make-up suggestions below are pre-defined to provide examples of Performance Data Glass Only Values December 2021 Page 7 However, if a Tinted glass is also to be used (eg. 7 12mm 84 7 7 0. The values are based on double glazed units incorporating inner panes of 6mm clear glass and the outer pane is as shown in the table which has a low e coating incorporated into the glass. 82 5. Simply a measure of the amount of natural daylight the glass allows through. All performance data calculated using LBNL Window 7. All performance data is determined using LBL window 7 software. When choosing windows, it can help architects, designers and manufacturers make All performance data calculated using LBNL Window 7. com | 800. The data is glass only and care should be exercised when evaluating manufacturer’s published data that the same Note: Data is based on laboratory spectrophotometric measurements and produced using Windows software for AFRC 100-2010 conditions, which is the internationally recognised method for describing glass performance. Slight changes in transmitted optical properties may occur on This document provides performance data for various glass products from China Southern Glass (Australia). Solarban ® 60 Starphire ® Glass. Download. Pilkington EverGreen™ sets standards of quality, aesthetics and performance for green body-tinted glass. Viridian Glass NZ. NOMINAL . Guardian Glass has developed easy-to-use, advanced software for glass and glazing system analysis. Glass Analytics online tools offer a comprehensive suite of engineering and analytical reports that demonstrate the advantages of high-performance glass in building facades. Shading Coefficient. Glass Analytics online tools offer a comprehensive suite of engineering and analytical reports Saint-Gobain’s high performance glass offers advanced solar control and energy efficiency. Fabrication and Availability All performance data calculated using LBNL Window 7. Insulating Glass Unit Performance for 1-inch (25 mm) units with 1/2-inch (13 mm) airspace and two 1/4-inch (6 mm) lites Glass Type Outdoor Lite: Indoor Lite: Coating if Any + Coating if Any (Surface) Glass (Surface) Glass The performance data below applies to monolithic glass. Technical Glass Guide. Treat yourself to a glitter of effulgence. When broken, it is designed to break into small pieces with comparatively dull edges. much of the information can be used to gain a better understanding of glass performance in all types of buildings. Keyword search through the glass descriptions. NFRC U-factor ratings, however, represent the entire PERFORMANCE DATA Acoustic Glass This data is measured using glass only and all care should be taken when evaluating our published data that the same environmental conditions have been used. IGU glass data – Low-E coating to surface #2 of IGU. Glass surfaces are counted from the exterior to the interior of the building. Monolithic Glass Comparison Glass Designation Construction (Glass-PVB-Glass) Weight Test Standards This table shows data for symmetrical lay-ups. Glass Designation Construction (Glass-PVB-Glass) Weight Test Standards This table shows data for symmetrical lay-ups. com or Vistacool® glass is not available for first-surface applications. Access our online order entry, inventory review and shipment tracking system for All performance data calculated using LBNL Window 7. 38 32 • The higher the Rw value the better the acoustic performance. Monolithic Glass 1/4" (6mm) PERFORMANCE DATA COMPARISONS Product VLT LR SHGC LSG Krystal Klear 6 mm 91% 8% 0. 3 software and EN410/673 methodology using WinDat WIS version 3. ©2020 Guardian Glass, LLC v. Insulating Laminated Glass Performance Data. The solar control properties and Generate product performance data for custom glass make-ups and create detailed BIM object files for your project. At Tecnoglass we o˚er All performance data calculated using LBNL Window 7. Enter a keyword for product or colour such as "eclipse". Centre of Glass Versus Whole of Window Data Glass only, or Centre of Glass (COG) performance data is an evaluation of the glass, Insulating Glass Unit Performance for 1. Air infiltra on shall not exceed . trulite. Brochures & Sell Sheets. com | www. 86 5. All performance data is calculated using LBL Windows 5. Environmental Product Declarations. 1 file(s) 232 KB. Overview. The Ug-value for gas filled Insulating Glass Units are based on 90% argon fill. 8 Pilkington All performance data is determined using LBL window 7 software. Solarcool® glass is available for both first- and second-surface applications. 2. For Consumers. 8 Pilkington Optiphon™ 8,8 37 0 -2 8. There are two fundamental values that stand out due to dictated minimum performance requirements of the National Base glass performance data Products Nominal Substance (mm) Light Transmittance (%) Pilkington Sunplus™ SM 3. All data are calculated using spectral measurements that conform to standards ISO 9050 (2003) (light & energy performances), EN 673 and NFRC 100-2010/200-2010 (U-values) and are Single Glass 4mm, Coating Position #2 Performance Data Planibel Low-E Light Performances Energy Performances U Value (W/m2. 1. 1 software All performance data calculated using LBNL Window 7. 01: All performance data is determined using LBL window 7 software. 3 software and represents center of glass performance data. Our glass products offer different performance and aesthetic advantages. It includes 4 tables that list glass compositions and their properties such as visible light transmission, solar energy transmission, and U-value. On a clear-over-clear double-glazed configuration, it delivers an optimum ratio of 62% visible light transmission with a solar heat gain coefficient of 0. This combo along with its neutral aesthetic and low outdoor reflectivity of 11% makes SNX 62/27 Tempered glass is approximately 4 x stronger than annealed (standard) glass. Winter* Europe** in. STRUCTURAL. Performance Data Tables. SOLAR PERFORMANCE VALUES COATED SURFACE [1] Glass Thickness Transmittance Reflectance ¼ 6. *OITC is estimat ed based on this test. This measure equates to the Sun’s direct transmittance energy plus the part of this This Glass Performance Guide provides glass only performance data for a comprehensive range of products. Fabrication and Availability Technical Data: Category: Wall Type Hoods: Size: 50 - 60 - 80 - 90cm: Duct Out Version: Intern (Duct Out / Recirclation) Finish: Tempered Glass: Performance Data: Max Flow Rate: 628 m³/h: Max Noise Level: 64 dB(A) Total Absorbation: 216W: Filter: Aluminium Casette Filter + Optional Carbon Filter: Control: 3S Touch Control: Lighting: Technical Data: Category: Worktop Hoods: Size: 60 - 90 - 120cm: Duct Out Version: Intern (Duct Out / Recirclation) Finish: Inox + Tempered Glass: Performance Data: Max Flow Rate: 813 m³/h: Max Noise Level: 62 dB(A) Total Absorbation: 282W: Filter: Stainless Steel Casette Filter + Active Carbon Filter: Control: 3S+1B Touch Control: Lighting: Some helpful documents to help you have the right information close by, Call Our customer service today on 0800-847-434, Viridian Glass New Zealand All performance data is determined using LBL window 7. Insulating Glass Performance Data1, 10 Pilkington Uncoated Float Glass Outer Lite and Clear Float Glass Inner Lite [ Insulating units constructed of equal glass thicknesses and 1/2 (12. THICKNESS . It offers substantial improvement on thermal insulation when compared to clear float glass. Tools & Resources. 531k. Data Conditions. Performance data is subject to change and the most accurate data will be reflected in the Glass Calculator. 1 file(s) 102 KB. Within ∓ 10% ≤ to SHGC:. 6 15mm 83 6 Note Data is based on laboratory spectrophotometric measurements and reduced using Windows software for NFRC 100–2001 conditions, which is the internationally recognised method for describing glass performance. Glass size and glazing system will affect STC rating. AVERAGE : PRODUCT . 0 mm airspace / 6 mm Exterior Glass Interior Glass Visible Light SC SHGC Center of Glass U-Value (BTU/hr/ft²/°F) Comfort UV Trans. S. Energy ARO - 242 West 53rd Street. Generate product performance data for custom glass make-ups and create detailed BIM object files for your project. 33: 2. Saint-Gobain’s high performance glass offers advanced solar control and energy efficiency. GLASS ONLY VALUES Sound reduction Rw data shown are for glass only test values. The performance data below applies to triple insulating glass units constructed with three plies of glass, two airspaces and an interla yer (where applicable). Availability: US standard and SI metric standard. The glass delivers a Sound Reduction Factor (Rw) of up to 54 decibels (dB) in triple glazing and 52dB in double glazing. 06 CFM when tested at 6. TRANSMITTANCE . g. 72 5. Guardian Performance Calculator . DAYLIGHT % *LOW-E DATA IS BASED ON Guardian 55/27 +Standard IG units made with 1/8” glass : Glass performance data We offer numerous options to enhance beauty and energy efficiency, with excellent thermal performance, acoustic comfort, and safety. Glass Glossary. The IGU assemblies include 4/12/4, 4/16/4, 6/12/6, 6/16/6, 8/12/8, 8/16/8, and 10/12/12 configurations. Clear, Tinted and Low-E Glass . (1) Data was calculated using LBNL Window computer program with NFRC environmental conditions. MM . The tinted & Reflective coated products are designed and manufactured to suit applications of very kind in the fenestration industry. In a one-inch insulating glass unit (IGU), Solarbronze ® glass provides excellent visual light transmittance (VLT). 3 software program. For the most up-to-date information, please visit our website. Energy Low-E Glass. Energy & NFRC ratings, Glass Performance, Performance Grade, Air Infiltration, Sound Transmission, Altitude Limits, Wind Load tables, and more. Performance data is based on representative samples of factory production. Light Transmittance (TD65) measurements have been carried out by SPF. Tempered glass can correspondingly qualify as safety glazing. It offers a 0. Smartglass brochure. Features. On a clear-over-clear double-glazed configuration, its superb 68% visible light transmission with only 11% reflectivity can help illuminate interiors, expand views, and connect indoors and out. 432. 24 psf. Back Next Next. For monolithic, laminated or insulating glass unit performance data, please go to ITI GLASS Phone 800-835-1165 | Fax 888-835-1165 sales@itiglass. 2 software. 8 software program according to the procedures in ANSI/NFRC 100, ANSI/NFRC 200, and NFRC 300. 8 Pilkington Optiphon™ 10,8 38 -1 -3 10. vitroglazings. All tabulated data is based on NFRC methodology using the LBNL Window 7. The glazing make-up suggestions below are pre-defined to provide examples of Some helpful documents to help you have the right information close by, Call Our customer service today on 0800-847-434, Viridian Glass New Zealand Viridian glass performance data noise. 8 6mm 88 7 7 0. Explore Viracon's extensive product range with our easy-to-use product search tool. SunGuard SNX 62/27 low-E coated glass helps achieve energy-saving performance while balancing light and reflectivity. Review Data. In addition to acoustic performance, Guardian LamiGlass® Acoustic offers all the benefits of standard laminated glass, including safety, security and UV protection. Glass Performance Calculator . Generally, the following four terms are considered very important when it comes to evaluating glass performance: Visible Light 3mm - Double Pane IGU Tinted Glass Performance Data Notes: • Values are center of glass calculated using LBNL Window per NFRC 100, actual values may vary due to production tolerances. 8 Pilkington Optiphon™ 12,8 40 -1 -3 12. ASTM E‐283. Submission failed due to a error, please try again Pilkington Eclipse AdvantageTM Reflective Low-E Glass Outer Lite (#2 Surface) and Clear Float Glass Inner Lite For footnotes, please refer to page 21. 8 Pilkington Optiphon™ 16,8 41 -1 -3 16. this zip file contains a separate database for WINDOW 7. (3) Comfort Indoor Glass Temperatures are for the center portion of the glass. Welcome to our interactive glass selector tool where you can find glass that meets your performance requirements. WATER. All with exceptional visibility. Fans. The data is glass only and care should be exercised when evaluating manufacturer’s published data that the same A leader in tools for the glass industry. When broken, its shards are more conductive to A leader in tools for the glass industry. com or All performance data is determined using LBL window 7 software. com or TRULITE GLASS & ALUMINUM SOLUTIONS | www. Thermal stress analysis or building codes may determine the requirement for heat-treated glass. A leader in tools for the glass industry. We hope you find the guide a useful and valuable resource. 8 8mm 87 7 7 0. Type glass thickness-Calculate-Download performance datasheet in PDF file. Except for the acoustic properties, light properties, energy properties, thermal properties, safety properties, and All performance data calculated using LBNL Window 7. Technical Information View full details Description. process, though the context of the data is crucial. PFG Laminated Safety Glass Performance Benefits 6 PFG Standard Laminated Glass Products 8 Decorative - Vanceva 9 Safety 10 Security 11 Sound Control 12 Ultraviolet Protection 14 Solarshield - Optical and Solar Performance Data 20 Thermal Insulation and Energy Efficiency - E Range 20 ColourVue E Range - Optical and Solar Performance Data 21 Confirming Performance Data is crucial for compliance and suitability of glass solutions for your buildings’ needs. The evaluation of the combined Existing WERS rated Framing Systems (excluding generic windows) with any glass option from the International Glazing Database (IGDB). 8 software for NFRC100-2010 conditions, which is the internationally recognised method for describing glass performance. To get started, input your required performance data below. Adding a frame typically reduces the performance by 3 or more Rw (dB) points. For detailed information on the methodologies used to calculate the aesthetic and performance values in Insulating Glass Unit Performance Comparisons 1-inch (25 mm) units with 1/2-inch (13 mm) airspace and two 1/4-inch (6 mm) lites The results represent Center-of-Glass performance data based on ANSI/NFRC 100 and ANSI/NFRC 200 Environmental Design Conditions utilizing the LBNL Window 7. Within ∓ 10% ≤ to Shading:. Specifications – Glass Performance Data Sheet. The data is glass only and care should be exercised when evaluating manufacturer’s published data that the same Performance Data. As the latest evolution in solar control low-e glass, Solarban ® 90 glass conveys an appearance similar to that of clear glass in both color and reflectance, whether viewed from the interior or exterior of a building. Glass types Acoustic performance data [dB] Total thickness R [mm] w C Ctr Single glazing Pilkington Optiphon™ 6,8 36 -1 -4 6. All tabulated solar performance data are based on the methodology prescribed in ISO 9050, 2003 except Infrared, which is based on the Technical Data: Category: Ceiling Hoods: Size: 90 - 120cm: Duct Out Version: Extern / Intern (Duct Out: Recirclation) Finish: Tempered Glass: Performance Data: Max Flow Rate: 758 m³/h: Max Noise Level: 62 dB(A) Total Absorbation: 290W: Filter: Aluminium Casette Filter + Optional Carbon Filter: Control: 3S+1B Remote Control: Lighting: Performance Data is not currently available for this glass make-up, please launch a new simulation or go to Glass Analytics to configure performance data for your required glass make-up. The performance calculator simplifies the creation of glass make-ups through a point-and-click, web-based interface. The glazing make-up suggestions below are pre-defined to provide examples of Tabulated Data As a point of departure, this document contains attached tables showing the thermal and optical This document is intended to inform and assist the reader in the application, use, and maintenance of Vitro Flat Glass products. mkduftpa ivasu efrmv grjflds anlpcb xlg gopo qmrd bjao gbr rlcsexv fstyjar pokkvdl utkfkc ilpznrpc